HH0-280 Free Demo Download
Certinside offers free demo for HH0-280 111 Q & As with Expert Explanations). You can check out the interface, question quality and usability of our practice exams before you decide to buy it.
Download HH0-280 Exam Pdf Demo
Download HH0-280 Exam iEngine Demo
Exam : Hitachi HH0-280
Title : HDS Implemetation Specialist – Storage Management
1. In Hitachi Storage Services Manager (HSSM), which two steps are required when discovering a host? (Choose two.)
A. Provide the administrator password.
B. Provide the IP address of the host to be discovered.
C. Install the appropriate CIM extension on the server you want to manage.
D. Click the Set Default User name and Password link and provide up to three user names and passwords.
Answer: BC
2. In a new installation of Hitachi Storage Services Manager (HSSM) which command is used to install the Oracle Patch?
A. "orapatch.sql"
B. "orapatch.exe"
C. "installPatch.cmd"
D. "patchupgrade -P -O d:"
Answer: C
3. Your 5 TB Hitachi Dynamic Provisioning (HDP) Pool contains one hundred 50 GB LDEVs and is running out of space.
Which two statements are correct? (Choose two.)
A. You create a new Pool and concatenate it with the existing Pool.
B. You create new LDEVs out of free space which are used as HDP Pool Volumes to expand your HDP Pool.
C. You install a new RAID group and create HDP Pool Volumes in this RAID group and add these to your HDP Pool.
D. You create a new Pool which meets the space requirements and you migrate the Virtual Volumes into this newly created Pool.
Answer: BC
4. Which two operating systems running on the Hitachi Dynamic Link Manager (HDLM) hosts are supported by Hitachi Global Link Availability Manager (HGLAM)? (Choose two.)
A. IBM AIX 5.3
B. IBM z/OS 1.6
C. Sun Solaris 8
D. Windows NT 4.0
Answer: AC
5. You are installing Hitachi Device Manager for Windows on a network where resources that are to be managed by the management server are inside a firewall.
What is required for these objects to communicate with the management server?
A. Use the setup utility to add ports to the firewall exceptions list.
B. Configure the firewall to allow these objects to communicate through each port with the management server.
C. Configure the firewall to allow these objects to communicate through each port with the management server. Use the setup utility to add ports to the firewall exceptions list.
D. Add the IP addresses of the managed host to the jpchostfile and to the jpchostfile of the Device Manager Server. Use the setup utility to add ports to the firewall exceptions list.
Answer: B
6. A customer wants to use Hitachi Dynamic Provisioning (HDP) on a USP V.
Which two statements are true regarding the mapping of Dynamic Provisioning (DP)-Volumes to the application? (Choose two.)
A. Any LDEV can be used as a DP-Pool Volume.
B. Any type of RAID group is available for DP-Pool Volumes.
C. The size of a DP-Pool is limited by the size of the DP-Pool LDEVs (max 1 TB).
D. The size of a DP-Pool is limited by the number of the DP-Pool LDEVs (max 256).
Answer: BD
7. A customer has five hosts available to install the Hitachi Device Manager (HDvM) server; a Solaris server with 512 MB of RAM; a Linux server with 1 GB of RAM; a AIX server with 4 GB RAM; and an active/passive Windows cluster running Hitachi Storage Services Manager (HSSM) (each node has 4 GB RAM).
On which server can HDvM be installed?
A. AIX
B. Linux
C. Solaris
D. Windows
Answer: B
8. A Hitachi Storage Services Manager (HSSM) customer has switches, hosts, and storage. They want to reduce their Get all Element Details (GAED) times.
Which recommendation should you make?
A. Use segmented replication.
B. Put everything in one discovery group.
C. Use the GAED wizard to reduce the time of each element.
D. Increase the memory of the server to reflect the number of discovery groups.
Answer: A
9. A customer is deploying a new USP V into the data center across various servers and operating systems. During the planning stage you identify Hitachi Dynamic Link Manager (HDLM) 5.8 as the preferred path management software on the AIX servers.
Which three must you include in a prerequisite check list for the deployment? (Choose three.)
A. Check that Hitachi Device Manager (HDvM) agent is not installed.
B. Include additional planning for any Virtual I/O (VIO) servers.
C. Check that the Object Data Manager (ODM) update is installed.
D. Check that Hitachi Device Manager (HDvM) is compatible with HDLM.
E. Check the operating system levels and fix packs against the release notes.
Answer: BCE
10. A customer is currently using Hitachi Device Manager (HDvM) server with a NIC plugged into a public LAN. This server also has another NIC attached to a private LAN where the Enterprise and Modular storage systems under management are located. The server has currently IP forwarding enabled to route physical view launching by Web clients.
Which proposal will provide a more secure configuration and still allow physical view usage from Web clients on the public LAN?
A. Add a firewall between the HDvM server and the private LAN; disable IP forwarding.
B. Add a firewall between the HDvM server and the public LAN; disable IP forwarding.
C. Add a firewall between the private and public LANs; remove the private LAN connection from the HDvM server.
D. Add a firewall between the private and public LANs; remove the public LAN connection from the HDvM server.
Answer: D
11. You have a customer that is running Hitachi Device Manager (HDvM) to manage their 9900Vs, USPs, and Adaptable Modular Storage (AMS) systems. Your customer wants to change the port number used by all of the AMS systems for TCP/IP communications.
Which two statements are correct? (Choose two.)
A. The port number for the AMS systems cannot be changed.
B. You must use Storage Navigator Modular to change the port setting in the AMS system.
C. You set the new port number in the Services file for the machine where HDvM server is installed.
D. You set the new port number in the Server.Properties file for the machine where HDvM is installed.
Answer: BC
12. A customer has Hitachi USP V, Hitachi AMS, EMC DMX, and HP EVA storage systems attached to twenty Windows servers and ten Solaris servers.
In this scenario, which two Hitachi Dynamic Link Manager (HDLM) configurations are supported? (Choose two.)
A. HDLM for UNIX for all storage systems
B. HDLM for Windows for all storage systems
C. HDLM for UNIX for Hitachi storage systems only
D. HDLM for Windows for Hitachi storage systems only
Answer: BC
13. You support a customer that will be implementing a Hitachi Device Manager (HDvM) solution. They plan on using HDvM to manage several USP600s and Adaptable Modular Storage (AMS) systems.
Which statement is correct to manage the AMS systems with HDvM?
A. Storage Navigator is required to use the Physical View.
B. Mapping Guard is required to set up security for the LUNs.
C. Storage Navigator Modular Link and Launch must be set up.
D. Disklock is required to use a lock system for devices accessed from HDvM.
Answer: C
14. Your customer is using Hitachi Device Manager (HDvM) to manage their storage systems. They also want to provision storage with Hitachi Provisioning Manager.
To allow provisioning of storage, which two tasks must be performed? (Choose two.)
A. Install HDvM agent.
B. Install Provisioning Manager.
C. Install CIM agent extensions.
D. First allocate the host to a Resource group.
Answer: AB
15. Your customer currently has Hitachi Dynamic Link Manager (HDLM) version 4.7 running on ten of their production servers. They want to simplify the management of running those HDLM instances.
What are two prerequisites for the hosts that are running HDLM to be managed by Hitachi Global Link Availability Manager (HGLAM)? (Choose two.)
A. Upgrade the HDLM instances to version 5.7 or higher.
B. Install Provisioning Manager agent 3.5 or later on the hosts running HDLM 4.7.
C. Install Hitachi Device Manager agent 3.5 or later on the hosts running HDLM 4.7.
D. Install Hitachi Device Manager agent 3.5 or higher after the upgrade to HDLM 5.2.
Answer: AD
16. A customer has an IBM storage array and is planning to use it as External Storage on the USP V to migrate an application LUN from external to internal.
Would this migration be disruptive for the application?
A. No, because the customer is using Tiered Storage Manager.
B. No, because the customer has a ShadowImage copy of the LUN.
C. Yes, because the server has to perform a reboot to see the LUN.
D. Yes, because the application must reconfigure the LUN presented by the USP V.
Answer: D